» Natural Gas Special Valve » Gas Emergency Shut-off Valve
  • Gas Emergency Shut-off Valve

    Product diameter: DN15~350
    Suitable medium: natural gas, hydrogen, gas, liquefied gas, gas, etc
    Principle and structure: distributed piston type, one-step piston type
    Working pressure: 0-0.1mpa, 0-0.4mpa, 0-0.6mpa
    Control mode: normally closed (manual reset and power on, 24 hours power on)
    Nominal pressure: PN16
    Connection method: flange
    Closing time: 0.1s
    Ambient temperature: - 50 ~ + 150 ℃
    Medium temperature: - 30 ~ + 80 ℃

    • Description

    Gas Emergency Shut-off Valve

    Introduction:

    Product use: the gas emergency shut-off valve (normally closed type) is used with the gas monitoring instrument. When the instrument detects the leakage of combustible gas, the monitoring instrument outputs a signal, and the solenoid valve automatically closes the valve quickly to cut off the gas supply, so as to prevent the occurrence of malignant accidents in time. The valve is applicable to gas supply pipe network, gas thermal energy workshop, gas boiler and gas system of residential buildings.

    Installation requirements:

    1. Since the piston of the emergency shut-off valve is reset by gravity and spring, the medium flow direction is horizontal during installation, and the pull rod is vertical at the upper end. It is strictly prohibited to invert or tilt!

    2. It is recommended to install a manual gate valve at the front of the emergency shut-off valve to facilitate the maintenance of the emergency shut-off valve in the future, so as not to affect the normal gas consumption.

    3. Install a rainproof shed on the installation of the emergency shut-off valve to prevent the coil from being wet by water for a long time, which will affect the service life of the valve.

    4. It is recommended to act once a month to keep the emergency shut-off valve in good working condition at any time.

    5. Do not hit the reset lever forcefully, otherwise the valve cannot be opened and closed normally.

    6. It is strictly prohibited to disassemble the emergency shut-off valve without permission, and it shall be repaired by professional gas technicians.

    Product Showing:

     

    Enquiry Form ( we will get back you as soon as possible )

    Name:
    *
    Email:
    *
    Message:

    Verification:
    3 + 6 = ?

    Maybe you like also

  • ABOUT US

    The company is committed to providing customers with a complete set of industrial valve solutions. Products are widely used in oil, natural gas, oil refining, chemical industry, power plants and other industrial fields with harsh working conditions and large demand around the world.

  • OUR PRODUCTS

    Marine Valve

    Natural Gas Special Valve

    Petrochemical Valve

    Power Station Valve

  • CONTACT US

    15-4, Building A, Longjing Rd, Yubei District, Chongqing 401122, China.

    Tel: +86-23-67956606 or +86-23-67304326

    Email: manager@hiseamarine.com

    Web: www.hiseavalve.com